Trident Data Upsampling
Examples
When handling C3Ds in Nexus, the ratio of the Vicon System data capture rate and the device data capture rate must be an integer. To ensure that this occurs, device data may need to be...
Nexus has many pathways to collect your data. The advantage of this is that you can configure it to do exactly what you need for your research project. If you’re new to using Vicon motion capture it can be confusing how...
When reconstructing and labelling your data you might have come across the problem of having extra marker trajectories that are almost the same location as what you think are the actual marker locations. Most of the time...
Vicon Nexus is a powerful software package that handles a range of input signals and performs powerful data handling and manipulation. Whilst it usually does a sterling job, sometimes, things go wrong. This page is...
Basic Video Transfer
Set Up FFDShow Codec for Vicon
Apply A Codec to Video
Video Overlay and Export
Introduction
Once you’ve captured data with your Vue cameras, you need to ‘transfer’ it to the...
It is now simple to read data into MATLAB without having to export and import CSVs. Nexus MATLAB integration allows MATLAB to access the open trial and import any of the data directly – trajectory, device, metadata or...
When using pipelines for processing gait data, the standard plug in gait pipeline is a great place to start but it is important to consider your specific application, system and processing requirements. This article will suggest some ways you may...
While it's important to backup data when using motion capture it is also important to create backups of configurations. The configurations include systems, pipelines, toolbars, monitors and more.
Some examples of when having backups easily...
It can be helpful to create one or even a range of custom pipelines to improve your processing workflow.
For example, if you are working with large amounts of data you may find it easier to use custom pipelines specifically for batch...
To connect analogue EMG signals into your Vicon System you will require a Vicon Lock Control Box, or in legacy MX systems an analog breakout box is required. For the purposes of this article we will focus on current systems.
Hardware
Your Lock...
If you have Plug in Gait data captured in Nexus 1 but wish to take full advantage of the features included in Nexus 2 you will need to convert your VST from Plug In Gait (PiG) to the newer Plug In Gait Ai (PiG Ai). By following these steps you...
When working with large data files in Vicon Nexus there are a coupe of options that can make processing trials simpler. Choosing which frames of the trial are loaded is one option, another option is choosing whether to load both or only one of...
When you are dealing with a large number of trials where you are repeating the same steps over and over again you may want to consider batch processing data. Batch processing is a handy tool in Nexus that will run the required pipeline for your...
There are a few ways to make your auto-labelling more reliable in Vicon Nexus 2. We will outline a few ways to perfect your process for auto-labelling.
Do your subject calibration
Our main piece of advice if you are struggling with the...
When capturing data, the frame outputs are based on the capture rate of your Vicon hardware capture rate. You might be thinking to yourself "My camera system is capturing at 200Hz but my EMG/force plate/other device is capturing at a higher rate...
Gap filling is required when a marker becomes occluded and cannot be accurately tracked. This can be a result of many things: a person moving away from the calibrated volume, a poor calibration, or a marker being occluded...
Use the following process for connecting your force plates with analogue connection into Vicon Nexus.
There will be a set number of pin inputs your force plate will require. I will use an AMTI OR6 plates as an example which require the six...
To connect analogue signals into your Vicon System you will require a Vicon Lock Control Box, or in legacy MX systems an analog breakout box is required. For the purposes of this article we will focus on current systems. We have specialised...
Occasionally users will have issues with not being able to record in Vicon Nexus. Usually this happens right when you have your patient, participant or customer arrives causing a small (or large) amount of panic.
The simplest way to find out...
It is fairly simple to check which firmware version each of your cameras are using, it can be done in only three steps!
In Resource pane, select the camera/s you wish to check.
Once selected check the properties and press "Show...
There are several hardware options that can be used to record reference video with Nexus 2. These options are as follows:
Vue Camera
The Vue is the most recent video reference hardware from Vicon with Seamless integration via POE. Note:...
If one of your cameras will not connect to your live system please follow this guide.
Visually check that the camera is on/receiving power by seeing if any indication lights are on. If it is not:
Check cable is connected to the camera...